Antari Onboard DMX Guia do Utilizador Página 11

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 10
9
Maintenance
The Ice fogger requires almost no maintenance. However, you should keep the unit clean. Disconnect the
mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid.
Do not use alcohol or solvents.
Keep connections clean. Disconnect electric power, and then wipe the connections with a damp cloth. Make
sure connections are thoroughly dry before linking equipment or supplying electric power.
Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container and
the fog machine liquid tank immediately after filling.
After every 40 hours of continuous operation, it is recommended to run a cleaning solution composed of
80% distilled water / 20% white vinegar through the system to prevent the accumulation of particulate matter
in the heating element.
When cleaning, use only a clean, lint-free soft cloth. An effective cleaning regimen is as follows:
1. Empty all fluid from machine. Add cleaning solution to tank. Plug unit in and begin warm up.
2. Run unit in a well-ventilated area until tank is empty.
3. Cleaning is now complete. Refill with liquid.
Performance Notes
All fog machines develop condensation around the output nozzle. Because this may result in some
moisture accumulation on the surface below the output nozzle, consider this condensation when
installing your unit.
Fog machines may sputter small amounts of fog occasionally during operation and for a minute or so
after being turned off.
All fog machines have a recycling period after bursts of fog, when the machine will shut itself down for a
short period in order to heat back up. During this time no fog can be produced. Warm-up is complete
when green lamp lights up on remote unit.
Troubleshooting
Antari Ice Fogger
This troubleshooting guide is meant to help solve simple problems.
Always monitor tank fluid level as you are fogging. Running a fog machine with no fluid can permanently
damage the unit.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operates
properly, do not carry out following steps.
If the fogger does not operate properly, refer servicing to a technician.
1. If you experience low output, mechanical pump noises other then the usual normal operating pump noise,
or no output at all, unplug immediately.
2. Check fluid level, the external fuse, remote connection, and power from the wall.
3. If all of the above appears to be O.K., plug the unit in again.
4. If fog does not come out after holding the remote button down for 30 seconds, check the hose attached to
the tank to make sure there is fluid going through the hose.
5. If you are unable to determine the cause of the problem, do not simply continue pushing the remote
button, as this may damage the unit.
6. Return the machine to your Antari dealer.